Quick answer

ASTM G155, ASTM G154 and ISO 4892 are accelerated weathering standards that differ mainly by light source. ASTM G155 uses xenon-arc lamps for full-spectrum, realistic weathering; ASTM G154 uses fluorescent UV lamps for aggressive UV durability screening; ISO 4892-2 and ISO 4892-3 are the international xenon-arc and fluorescent UV equivalents for plastics.

Key facts

  • ASTM G155 covers xenon-arc exposure of non-metallic materials using the full spectrum of UV, visible and infrared light.
  • ASTM G154 uses fluorescent UV lamps, usually alternating UV light with condensation cycles.
  • ISO 4892-2 corresponds to ASTM G155, and ISO 4892-3 corresponds to ASTM G154.
  • Xenon-arc methods correlate better with real-world color change because they reproduce visible and infrared light as well as UV.
  • T3 weathering chambers are sized from 20 CFT to drive-in scale.

ASTM G155, ASTM G154, ISO 4892 — they all “age materials with light,” so which one do you actually need? The choice comes down to the light source and the spectrum, and picking wrong can either under-test your product or produce failures that never happen in the real world. Here is how to decide.

Accelerated weathering tests speed up years of sun-and-weather exposure into weeks by intensifying the light — and sometimes adding moisture and heat — inside a controlled chamber. The three standards you will meet most often are ASTM G155, ASTM G154, and ISO 4892. They are not interchangeable. The right one depends on the material, the market you sell into, and whether you need a realistic full-spectrum simulation or an aggressive UV-only screen.

The key difference: light source

Every one of these standards is defined first and foremost by the lamp it uses, because the lamp determines the spectrum — and the spectrum determines what kind of degradation you reproduce.

  • Xenon-arc lamps produce a close match to the full spectrum of natural sunlight — UV, visible, and infrared. They reproduce realistic weathering, including colour change and heat effects.
  • Fluorescent UV lamps concentrate output in the ultraviolet band, the part of sunlight most responsible for breaking down materials. They accelerate UV damage aggressively but do not reproduce the full solar spectrum.

That single distinction — full-spectrum xenon versus UV-only fluorescent — is the fork in the road for choosing a standard.

ASTM G155 — xenon-arc weathering

ASTM G155 governs exposure of non-metallic materials in a xenon-arc apparatus. Because xenon reproduces the whole solar spectrum, G155 is the standard to reach for when you need realistic, full-spectrum weathering — fading, gloss loss, and appearance changes that correlate with real outdoor exposure. It is widely used for coatings, plastics, textiles, and pigments where colour and surface appearance matter. Xenon systems typically add controlled irradiance, temperature, and moisture (spray or humidity) to simulate a complete weather cycle.

ASTM G154 — fluorescent UV weathering

ASTM G154 governs exposure in a fluorescent UV apparatus, usually alternating UV light with condensation (moisture) cycles. Because it concentrates on the short-wavelength UV that drives photodegradation, G154 is an aggressive, cost-effective screen for durability — excellent for comparing formulations, checking UV stabiliser packages, and catching materials that will chalk, crack, or embrittle. It reproduces UV damage and dew-driven moisture attack, but not the visible/infrared portion of sunlight, so it is less suited to accurate colour-change prediction.

ISO 4892 — the international equivalent

ISO 4892 is the international standard family for laboratory light exposure of plastics, and it mirrors the ASTM split across its parts: ISO 4892-2 covers xenon-arc sources (the G155 counterpart) and ISO 4892-3 covers fluorescent UV sources (the G154 counterpart). If your customers or markets — particularly outside North America — specify ISO, you test to the matching part using the same lamp technology. Many chambers can run both the ASTM and ISO versions of a given method.

Side-by-side comparison

StandardLight sourceSpectrumBest for
ASTM G155Xenon-arcFull spectrum (UV + visible + IR)Realistic weathering, colour & gloss, coatings and plastics
ASTM G154Fluorescent UVUV-concentratedAggressive UV durability screening, formulation comparison
ISO 4892-2Xenon-arcFull spectrumInternational equivalent of G155 (plastics)
ISO 4892-3Fluorescent UVUV-concentratedInternational equivalent of G154 (plastics)

How to choose

  1. Does a customer or market specify one? If a spec names G155, G154, or an ISO 4892 part, that decision is made — test to it.
  2. Do you need realistic colour and appearance data? Choose xenon-arc (G155 / ISO 4892-2) for full-spectrum realism.
  3. Do you need a fast, aggressive durability screen? Choose fluorescent UV (G154 / ISO 4892-3) to concentrate on UV damage cost-effectively.
  4. Selling into ISO and ASTM markets? Specify a chamber that runs both so one asset covers both standard families.

How T3 handles this. T3’s solar simulation and weathering chambers run ASTM G155, ASTM G154, and ISO 4892 (Parts 2 & 3), plus SAE J2527 / J2412, MIL-STD-810 Method 505, and IEC 60068-2-5. They can be equipped with xenon-arc or fluorescent-UV sources — or configured to cover multiple methods — with filter-glass spectral conditioning and simultaneous temperature and humidity control. Sized from 20 CFT to drive-in scale, they are part of T3’s full range of environmental test chambers, US-built with lifetime engineering support.

For the bigger picture on how sunlight is reproduced in the lab, see our guide to solar climatic testing and solar simulation chambers.

Frequently Asked Questions

What is the difference between ASTM G155 and ASTM G154?

ASTM G155 uses a xenon-arc lamp to reproduce the full solar spectrum for realistic weathering, while ASTM G154 uses fluorescent UV lamps to concentrate on ultraviolet damage for aggressive, cost-effective durability screening.

Is ISO 4892 the same as ASTM G155 and G154?

They are equivalents. ISO 4892-2 (xenon-arc) corresponds to ASTM G155, and ISO 4892-3 (fluorescent UV) corresponds to ASTM G154. The choice usually depends on whether your market specifies ISO or ASTM.

Which weathering test should I use for colour change?

Use a full-spectrum xenon-arc method (ASTM G155 or ISO 4892-2). Because it reproduces visible and infrared light as well as UV, it correlates better with real-world fading and appearance change than UV-only fluorescent testing.

Can one chamber run both xenon and fluorescent UV tests?

Chambers are configured around the source, but a solar simulation chamber can be specified to run multiple methods so a single asset covers both the ASTM and ISO standard families. T3 configures chambers to the standards you need.

Not sure which weathering standard fits your product? Request a quote and a T3 engineer will help you match the right method and chamber to your materials and markets.

Standards referenced

T3 Engineering Team

T3 Engineering TeamApplications & Engineering

Written by the T3 engineering and applications team — with hands-on experience designing, manufacturing, and servicing environmental test chambers for aerospace, automotive, electronics, defense, and energy industries worldwide.

Veteran-OwnedSDVOSB Certified15+ Years Experience

Need Help With Your Testing Program?

Our engineers can help you select the right chamber for your application, test profiles, and compliance requirements.

Browse Chambers
Call